CAT: BFP/VCAR
CVR06
PRPP
T
Y
IE/CVR06/001/2011 SHEET: 1/1
CVR 06 * * ** 1
1 = CVR06.1..
2 = CVR06.2..
3 = CVR06.3..
4 = CVR06.4..
2
Ø 35
17
5
27
Ø 30
Ø 15.9
Ø 17.5
7/8" - 14 UNF
80 max
91 max
47.4
T
PP
PR
V
C
max 15 Nm
1
2
3
4
02.5 57.5 10 12.515 17.5 20
0
25
50
75
100
125
150
175
200
225
250
Q (l/min)
P(bar)
02.557.5 10 12.5 15 17.520
0
10
20
30
40
50
60
70
Q (l/min)
P(bar)
02.557.5 10 12.515 17.5 20
3
4
2
1
0
25
50
75
100
125
150
175
200
225
250
Q (l/min)
P(bar)
PRESSURE REDUCING VALVES WITH RELIEVING - DIRECT OPERATED
HYDRAULIC SYMBOL
HYDRAULIC FEATURES
CVR = Pressure reducing valve with
relieving
ORDERING CODE
Series
Size
Adjustment
06 = 7/8 - 14 UNF
C = Screw
V = Hand wheel
1 = Serial No.
00 = No variants
V1 = Viton
SEQUENCE, PRESS.REDUCING AND UNLOADING
PRESSURE-FLOW OF RELIEVING
MIN.SETTING PRESSURE
Setting
ranges
1 = 2 ÷ 30 bar (white spring)
2 = 6 ÷ 70 bar (yellow spring)
3 = 35 ÷ 130 bar (green spring)
4 = 65 ÷ 230 bar (blue spring)
Fluid used: mineral based oil with viscos-
ity 46 mm²/s at 40°C.
PRESSURE-FLOW RATE
Max. pressure 320 bar
Setting range:
Spring 1 (white)
Spring 2 (yellow)
Spring 3 (green)
Spring 4 (blue)
max 2 ÷ 30 bar
max 6 ÷ 70 bar
max 35 ÷ 130 bar
max 65 ÷ 230 bar
Max. Flow 20 l/min
Max. draining on port T 0.2 l/min
Hydraulic fluid DIN 51524 Mineral oils
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamin. level class with filter ISO 4406:1999 - class 19/17/14
Weight 0.3 kg
Tightening torque 35 ÷ 40 Nm
Cavity (7/8 - 14 UNF) CD019006 (See section 15)
The minimum permissible setting pressure depending on the spring: see curves.
Variants
The direct acting pressure reducing valve feeds a secondary branch of a circuit at
a lower pressure than the main branch, guaranteeing minimum variation of the set
pressure with flow alterations of up to 20 l/min.
Slight leakage is tolerated for this type of valve.
It raises the safety level with the RELIEVING system that enables fluid to pass
through the valve from PR to T, preventing pressure increases in the controlled
branch and protecting the load, and by making it impossible for plant operators
to set a higher pressure rating than that specified in the catalogue. It has a pack
spring with mechanical stop.
It has a galvanised steel body. The plunger is in tempered and ground steel.
00012014
Spare seals kit
Page: 33
HOME INFO VALVES INDEX